C2000console CONTROLLERUser Reference ManualandInstallation Guide
C2000General Information & Warranty‚ 4THE FOREGOING WARRANTY IS IN LIEU OF ALL OTHER WARRANTIES,EXPRESSED OR IMPLIED, INCLUDING, BUT NOT LIMITED T
C2000Operation‚ 5OPERATIONIntroductionIn this section, all functions available to the cashier for operationof the C2000 are outlined. Table 1 on the
C2000Operation‚ 6Active KeysPUMP KEYS Select pump numberAUTHORIZE Authorize selected pump or resume a stoppedpumpCASH PAID Pay out the sale in cashCRE
C2000Operation‚ 7Display and Status IndicatorsThe LCD display provides the cashier with all sale information forthe pump selected. It also provides d
C2000Operation‚ 8Figure 3: Display LayoutThe LEDs above each of the pump select keys are the statusindicators for that particular pump/fueling positi
C2000Operation‚ 9SalesAuthorization must be made for a sale as either a Postpay, PresetPostpay, or Prepay sale. Table 4, below, describes the sequenc
C2000Operation‚ 10If the transaction is a stacked sale (A/B), it is important to selectthe correct sale with the <A/B> key before the method of
C2000Operation‚ 11Select FunctionsListed below are the five special operator select functions, alongwith the key sequences required to execute them.
C2000Operation‚ 12This will scroll all of the shift totals. After exhibiting all of thetotals, the display will return to the select function entry s
C2000Operation‚ 13the Select Function menu. Press <SELECT> again to read theconsole clock.A special select function is required to turn off the
© Copyright 2001Progressive International Electronics2422 Atlantic AvenueRaleigh, North Carolina 27604Phone 919 821-1323 • Fax 919 821-1325www.pie-cor
C2000Program & Report‚ 14PROGRAM & REPORTIntroductionThe Program & Report Section describes the operation andresulting information provide
C2000Program & Report‚ 15PIN Code AccessTo access C2000 program and report features, a sequence utilizinga valid PIN Code must first be entered.Ac
C2000Program & Report‚ 16Operator AccessAccess to report functions is accomplished through the entry ofa valid Operator PIN Code. First, press th
C2000Program & Report‚ 17Mode DescriptionsThe sequence for manager access must be completed beforeprogramming features can be utilized through the
C2000Program & Report‚ 18To set the service mode, press the <CHANGE> key to togglebetween full- or self-service for the specified pump.If th
C2000Program & Report‚ 19the name will appear in the display.To set the Cash PPU for a product, enter the desired PPU on thenumeric keypad and pre
C2000Program & Report‚ 20Mode 3 — Beeper Settings (Manager only)Mode 3 is used to program single or continuous beeps forHandle, Collect and Drive-
C2000Program & Report‚ 21Mode 4 — Clock/Calendar (Manager only)Mode 4 allows the setting of time and date. To enter mode 4,press <4> and pr
C2000Program & Report‚ 22the display.Press <ENTER> to advance the menu. The display will nowprompt an entry for correct data bit selection.
C2000Program & Report‚ 23Mode 6 — Peripheral Devices (Manager only)Mode 6 enables the device(s) connected to the serial port. (TheC2000 default as
© Copyright 2001Progressive International ElectronicsC2000console CONTROLLERUser Reference ManualandInstallation Guide2422 Atlantic AvenueRaleigh, Nor
C2000Program & Report‚ 24Mode 7 — Print Header (Manager only)In this mode, the print header for the printer receipt is createdand edited. (Note t
C2000Program & Report‚ 25Print Header Character Codes01 = end of header 10 = new line0 48 F 70 U 85 j 106 y 121 - 45<961 49 G 71 V 86 k 107 z
C2000Program & Report‚ 26Special editing features are available for use in this mode:<ENTER> without entering a numeric code — The displaycu
C2000Program & Report‚ 27Select the report number and enter it on the C2000 keypad; thenpress <ENTER>. The beginning data for the report is
C2000Program & Report‚ 28Select the report number and enter it on the C2000 keypad; thenpress <ENTER>. Data for the report will be printed.
C2000Program & Report‚ 29Mode 98 — Program Manager PIN Code (Manager only)WARNING: Care should be observed while using this mode. If the PIN Code
C2000Installation‚ 30INSTALLATIONIntroductionThe Installation Section contains instructions for installing theC2000 to electronic fuel pump computers
C2000Installation‚ 31General Installation GuidelinesThe basic C2000 system consists of several components — theconsole, configurator box and cables to
C2000Installation‚ 32Installation WarningsWarning: Installation must comply with the National ElectricalCode, as well as Federal, State, Local and al
C2000Installation‚ 33Gilbarco Electronic Fuel PumpsRead entire installation section before attempting to install system. Take careful note of warnings
Copyright © 2001 Progressive International Electronics, Inc.All rights reserved. No part of this publication may be reproduced, stored in aretrieval
C2000Installation‚ 34Figure 5: Gilbarco TS1000 "D" Box Figure 6: Gilbarco Universal "D" Box 3. Test all the pumps in s
C2000Installation‚ 35 4. Turn all the switches in the Gilbarco "D" box to ISOLATE. Program the pump numbers into the pumps. Switch the&qu
C2000Installation‚ 36Tokheim Electronic Fuel PumpsRead entire installation section before attempting to installsystem. Take careful note of warnings
C2000Installation‚ 37 3. Attach the C2000 pump connection cable to the connectoron the Tokheim configurator box. Be sure to screwlockthis connecto
C2000Installation‚ 38For Pumps Using Tokheim Model 67 Connection Box: 1. Install pumps and connect wires to the Tokheim 67connection box according
C2000Installation‚ 39Kraus Micon 100 Electronic Fuel PumpsRead entire installation section before attempting to installsystem. Take careful note of w
C2000Installation‚ 40Figure 10: Configurator Box for Kraus 4-Hose SystemsFigure 11: Kraus Micon Pump Head
C2000Installation‚ 41PIN#SIGNAL PUMP #1 TTC1, 5, 9, 132DCC3 TTP4 TTC2, 6, 10, 145DCC6 TTP7 TTC4, 7, 11, 158DCC9 TTP10 TTC4, 8, 12, 1611 DCC12 TTPTable
C2000Installation‚ 42 2. If submerged turbine pumps are used, install the optionalturbine relay box. Refer to Figure 12 below.Figure 12: Turbine
C2000Installation‚ 43Wayne/Dresser Electronic Fuel PumpsRead entire installation section before attempting to installsystem. Take careful note of war
iC2000CONTENTSGENERAL INFORMATION & WARRANTY ... 1General Information ... 1C2000 Manufacturer's Warranty ...
C2000Installation‚ 44 3. Test all the pumps in stand-alone. Do not proceed until allpumps run in stand-alone. 4. Turn all the switches in the W
C2000Installation‚ 45Bennett Electronic Fuel PumpsRead entire installation section before attempting to installsystem. Take careful note of warnings
C2000Installation‚ 46 2. Connect the wall transformer into a 115 VAC receptacle.PIN # SIGNAL PUMP #1Orange (+)1, 92 Yellow (-)3Orange (+)2, 104 Yel
‚ 47NOTES
‚ 48NOTES
iiINSTALLATION ... 30Introduction ... 30General Installation Guidelines ... 31Insta
C2000General Information & Warranty‚ 1GENERAL INFORMATION & WARRANTYGeneral InformationThe C2000 is an economical, full-featured console desig
C2000General Information & Warranty‚ 2Standard features provided by the C2000 for efficient control ofyour fueling dispensers include: CFull featu
C2000General Information & Warranty‚ 3C2000 Manufacturer's WarrantyProgressive International Electronics, Inc. (SELLER) warrants to the Purch
Commentaires sur ces manuels